Carrier refrigerant piping design manual






















This part of the System Design Manual presents data and examples to the engineer in practical design and layout of normal air conditioning piping system. chapter4 refrigerant, brines, oils This part of the System Design Manual presents data to guide the engineer in the application and selection of refrigerants, brines and oils when used with air conditioning www.doorway.ruted Reading Time: 3 mins. Good refrigeration piping design requires that the refrigeration lines be pitched in the direction of flow at approximately 1/2 inch per 10 feet or 1 inch per 20 feet. Refrigerant velocities in vertical lines should be at least ft/min to ensure good oil return; velocities in horizontal lines should be at least ft/min. Suva refrigerants ®File Size: 1MB. The Refrigerant Piping Design program will select pipe size based on a specified maximum pressure drop in the line and compute minimum required capacity for oil entrainment in risers. The program eliminates all the tedious calculations necessary when piping is sized manually and automatically corrects for all system operating conditions, interpolating and adjusting data in the tables and charts.


The piping design of any air conditioning system will a˜ect the performance, reliability, and applied cost of that system. The design of refrigerant piping systems involves capacity and e˚ciency, reliability, oil management, refrigerant charge, sound level, liquid refrigerant control, modulation e˜ectiveness and cost. to pump refrigerant vapor, and will tolerate only a limited quantity of liquid refrigerant. 5. Proper refrigerant feed to the evaporator must be maintained, and excessive pressure drop in the refrigerant piping must be avoided. If these give steps are accomplished, then operation of the system is reasonably certain to be trouble free. If. Carrier eDesign Software Refrigerant Piping Design v Refrigerant Piping Design v will not replace v when it is installed. Therefore, when it is no longer needed, v can be uninstalled separately using the following procedure: Open Windows Control Panel.


Good refrigeration piping design requires that the refrigeration lines be pitched in the direction of flow at approximately 1/2 inch per 10 feet or 1 inch per 20 feet. Refrigerant velocities in vertical lines should be at least ft/min to ensure good oil return; velocities in horizontal lines should be at least ft/min. Suva refrigerants ®. The piping design of any air conditioning system will affect the performance, reliability, and applied cost of that system. The design of refrigerant piping systems involves capacity and efficiency, reliability, oil management, refrigerant charge, sound level, liquid refrigerant control, modulation effectiveness and cost. Description CARRIER SYSTEM DESIGN MANUAL PART 3: PIPING DESIGN. by Carrier University. Four chapters covering practical design and layout of air conditioning piping systems, including: general piping design, water piping, refrigerant piping, and steam piping. CARRIER SYSTEM DESIGN MANUAL PART 3: PIPING Page 7/

0コメント

  • 1000 / 1000